NetApp FAS3210 specs
We are currently working on upgrading our specs, but here are some short details.
Maximum Raw capacity - 480 TB
Maximum Disk Drives - 240
Controller form factor - Single enclosure HA; 2 controllers in single 3U chassis
Memory - 8 GB
Maximum flash cace - 512 GB
PCIe Expansion slots - 4
Onboard I/O 4Gb FC - 4
Onboard I/O 6Gb SAS - 4
Onboard I/O: GbE - 4
Storage networking - FC; FCoE; IP SAN (iSCSI); NFS; CIFS; HTTP; FTP
OS version - Data ONTAP 7 and 8
High-Availability features:
Alternate Control Path (ACP);
Ethernet-based service processor and Data ONTAP management interface;
redundant hot-swappable controllers, cooling fans, power supplies, and optics
Supported configurations:
Highly available controller configurations
Active-active controller with controller failover and multipath HA storage
Active-active controller with stretch (nonswitch) and fabric-attached MetroCluster™
V-Series
Storage Acceleration Appliance SA320
Disk Shelves Supported - DS2246 (2U; 24 drives, 2.5” SAS SFF 10K RPM 450GB/600GB)
DS4243 (4U; 24 drives, 3.5” SATA 7.2K RPM 1TB/2TB; 3.5" SAS 15k RPM, 450GB/600GB; 3.5” SSD 100GB)
DS14mk2 and DS14mk4 (3U; 14 drives, 3.5” FC 450GB/600GB, 3.5” SATA 1TB/2TB)
Maximum RAID Group Sizes - RAID 6 (RAID-DP)
FC: 28 (26 data disks plus 2 parity disks)
SATA: 20 (18 data disks plus 2 parity disks)
RAID 4
FC: 14 (13 data disks plus 1 parity disk)
SATA: 7 (6 data disks plus 1 parity disk)
Operating Systems Supported - Windows 2000, Windows Server 2003, Windows Server 2008, Windows XP, Linux, Sun Solaris, AIX, HP-UX, Mac OS, VMware, ESX
Maximum Number of LUNs - 4,096
Number of Supported SAN Hosts - Up to 512 hosts per HA pair
Up to 24 directly connected servers per HA pair
FlexVol Volumes - Up to 500 per controller
Snapshot Copies - Up to 127,000
Max volume/Aggregate Size - 50TB
FC Target (8Gb/4Gb) (max.) - 8/20
10GbE/FCoE Target ports - 8
GbE (max) - 20
6Gb SAS (max.) - 20
FC initiator (max) - 20
Thermal rating - 1577 BTU (typical) 2137 BTU (worst case)
Weight - 80 lb
Height - 5.1" (13cm) fits into 3U space
Width - 19" IEC rack-compliant (17.6", 44.7 cm)
Depth - 24" (26.5" w/cable management)
Operating temperature, Altitude and Relative Humidity - 10° C to 40° C (50° F to 104° F); at <= 3,000 m (at <= 10,000' feet) elevation; 20% to 80% relative humidity, noncondensing (28° C wet bulb temperature)
Nonoperating Temperature - -40° C to 65° C (-40° F to 149° F); 5% to 95% relative humidity, noncondensing, in original container
Operating Acoustic Noise - ≤ 61 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level)
Maximum Disk Drives - 240
Controller form factor - Single enclosure HA; 2 controllers in single 3U chassis
Memory - 8 GB
Maximum flash cace - 512 GB
PCIe Expansion slots - 4
Onboard I/O 4Gb FC - 4
Onboard I/O 6Gb SAS - 4
Onboard I/O: GbE - 4
Storage networking - FC; FCoE; IP SAN (iSCSI); NFS; CIFS; HTTP; FTP
OS version - Data ONTAP 7 and 8
High-Availability features:
Alternate Control Path (ACP);
Ethernet-based service processor and Data ONTAP management interface;
redundant hot-swappable controllers, cooling fans, power supplies, and optics
Supported configurations:
Highly available controller configurations
Active-active controller with controller failover and multipath HA storage
Active-active controller with stretch (nonswitch) and fabric-attached MetroCluster™
V-Series
Storage Acceleration Appliance SA320
Disk Shelves Supported - DS2246 (2U; 24 drives, 2.5” SAS SFF 10K RPM 450GB/600GB)
DS4243 (4U; 24 drives, 3.5” SATA 7.2K RPM 1TB/2TB; 3.5" SAS 15k RPM, 450GB/600GB; 3.5” SSD 100GB)
DS14mk2 and DS14mk4 (3U; 14 drives, 3.5” FC 450GB/600GB, 3.5” SATA 1TB/2TB)
Maximum RAID Group Sizes - RAID 6 (RAID-DP)
FC: 28 (26 data disks plus 2 parity disks)
SATA: 20 (18 data disks plus 2 parity disks)
RAID 4
FC: 14 (13 data disks plus 1 parity disk)
SATA: 7 (6 data disks plus 1 parity disk)
Operating Systems Supported - Windows 2000, Windows Server 2003, Windows Server 2008, Windows XP, Linux, Sun Solaris, AIX, HP-UX, Mac OS, VMware, ESX
Maximum Number of LUNs - 4,096
Number of Supported SAN Hosts - Up to 512 hosts per HA pair
Up to 24 directly connected servers per HA pair
FlexVol Volumes - Up to 500 per controller
Snapshot Copies - Up to 127,000
Max volume/Aggregate Size - 50TB
FC Target (8Gb/4Gb) (max.) - 8/20
10GbE/FCoE Target ports - 8
GbE (max) - 20
6Gb SAS (max.) - 20
FC initiator (max) - 20
Thermal rating - 1577 BTU (typical) 2137 BTU (worst case)
Weight - 80 lb
Height - 5.1" (13cm) fits into 3U space
Width - 19" IEC rack-compliant (17.6", 44.7 cm)
Depth - 24" (26.5" w/cable management)
Operating temperature, Altitude and Relative Humidity - 10° C to 40° C (50° F to 104° F); at <= 3,000 m (at <= 10,000' feet) elevation; 20% to 80% relative humidity, noncondensing (28° C wet bulb temperature)
Nonoperating Temperature - -40° C to 65° C (-40° F to 149° F); 5% to 95% relative humidity, noncondensing, in original container
Operating Acoustic Noise - ≤ 61 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level)
also know as: NetApp FAS3200 Series
If you are interested in using our specs commercially, check out our Network Attached Storage specs database licensing page.
Filed in: NetApp Network Attached Storage